BCQMT - HANDI-STIK AEROSOL, 5027

Product Identification

Product ID:HANDI-STIK AEROSOL, 5027
MSDS Date:01/01/1987
FSC:8040
NIIN:00N008533
MSDS Number: BCQMT

Responsible Party
NATIONAL CHEMSEARCH (NCH CORP.)
2727 CHEMSEARCH BLVD
IRVING, TX 75015
US

Cage: DO481

Contractor
NCH CORP
152170 IRVING, TX 75015-2170 US

Telephone: 972-438-0563

Cage: 20913

Ingredients

METHYLENE CHLORIDE (SARA III)

CAS: 75-09-2

RTECS: PA8050000

OSHA PEL 500 PPM/C,1000; Z2

ACGIH TLV: 50 PPM, A2; 9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


TOLUENE (SARA III)

CAS: 108-88-3

RTECS: XS5250000

OSHA PEL 200 PPM/150 STEL

ACGIH TLV: 50 PPM; 9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


METHYL ABIETATE (CAS# 127-25-3)

CAS: 127-25-3

RTECS: TP8590000

ACGIH TLV: NOT ESTAB (MFR)

Hazards

Effects of Overexposure:VAPORS ARE NARCOTIC,POSS CNS DEPRESSION LEADING
TO HDACH,DIZZY,NAUSEA,UNCONSCIOUS.(SEE SUPP DATA)

First Aid

First Aid:EYE:FLUSH W/PLENTY OF H*20 FOR @ LEAST 15 MIN.SEE MD IF
IRRIT.SKIN:WASH W/SOAP,H*20.INHAL:MOVE TO FRESH AIR,TREAT
SYMPTOMS.SUPPORT BRTHG(GIVE O*2/ARTF RESP).CALL MD.INGEST:DONT
INDUCE VOMIT EVEN IF VOMIT OCCURS;IF OCCURS KEEP HEAD(SEE OTHR
PREC

Fire Fighting

Flash Point:80F, PROPELLANT
Extinguishing Media:FOAM,CO*2,DRY CHEMICAL.
Fire Fighting Procedures:NIOSH/MSHA APPROVED PRESS DEMAND SCBA,FULL
PROT CLTHG
Unusual Fire/Explosion Hazard:VAP HEAVIER THAN AIR,MAY COLLECT IN LOW
AREA/INADEQUATELY VENT AREA.THERMAL DECOMP PROD:HCL,PHOSGENE

Accidental Release

Spill Release Procedures:AEROSOL SO SPILL UNLIKELY.IF LEAKAGE,PICK UP
W/ABSORBANT (PAPER,VERTICULITE,ETC.) TO CONTAIN SPILL.DONT FLUSH TO
SEWER.PLACE IN LABELED CONTANER & SEAL.WET VACUUM AREA AFTER ALL
TRACES HAVE BEEN CLEAN ED UP.

Handling

Handling and Storage Precautions:STORE BETWEEN -50F & 120F
INDOORS/OUTDOORS ON SIDE.STORE IN ORIGINAL CNTNR ONLY.FOLLOW LABEL
DIRECTION.KEEP FROM CHILDREN.DO NOT WEAR CONTACTS.
Other Precautions:NO SMOKING IN AREA.DONT USE IN GENL VICINITY OF ARC
WELDING,OPEN FLM/HOT SURF.HEAT/UV RADIATION MAY CAUSE HCL/PHOSGENE
FORMATIONFIRST AID:BELOW HIPS TO PVNT ASPIRATION.GET MED ATTN IMMED

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXP OF CONCERN
Ventilation:SUFFICIENT VENTILATION TO BE BELOW ALLOWABLE
CONCENTRATIONS.
Protective Gloves:VITRON,PVA
Eye Protection:CHEMICAL WORKERS GOGGLES
Other Protective Equipment:HEAD GEAR & APRON WHEN SPRAYING
Supplemental Safety and Health
METHYLENE CHLORIDE:SUSPECT OF CARCINOGENIC POTENTIAL FOR MAN).
OVEREXP:CHRONIC-CNS DEPRESSION,LIVER DAMAGE & LIVER/KIDNEY
EFFECTS.SKIN DERMATITIS POSS. DATE OF PREP:11-12-85.

Chemical Properties

Boiling Pt:B.P. Text:105F (41C)
Vapor Pres:260
Vapor Density:2
Spec Gravity:1.25
Evaporation Rate & Reference:(BU AC)
Solubility in Water:INSOLUBLE
Appearance and Odor:COLORLESS,SEMI-VISCOUS,SLIGHT TURBID;SOLVENT ODOR.
Percent Volatiles by Volume:814

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS/BASES & SELECTED AMINES;ALSO ALUMINUM.
Stability Condition to Avoid:OPEN FLAMES
Hazardous Decomposition Products:CAN @ DECOMP TEMP RELEASE
CO*2,CO,PHOSGENE & HCL.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL,STATE &
LOCAL REGULATIONS.DO NOT INCINERATE/PUNCTURE CAN.DISPOSE OF CAN
ALONG WITH CONTAMINATED ABSORBANT IN APPROVED SANITARY LANDFILL.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.